Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Gelco Fireplace Services in Kirkland: What to Know First
We provide independent Gelco fireplace services in Kirkland, from gas insert tune-ups to firebox rebuilds, with a written price before any work starts and a camera-scan inspection included on every visit. Most Gelco jobs are scheduled within a week and completed in a single appointment. We’re not affiliated with Gelco - we buy parts through our Haven Standard buying network and service what we find, not what a manufacturer hopes you’ll replace.
This page is for Kirkland homeowners who own a Gelco gas fireplace, wood-burning unit, or insert and need honest diagnostics on whether the fix is a $180 damper adjustment or a $2,400 liner replacement. If you’re seeing soot on the glass, smelling gas, or your blower won’t stay on, call us at (425) 642-3485. We’ll send a written estimate before anyone picks up a tool.
What happens when you call
- 1
A real person answersNo phone trees - you reach a local pro.
- 2
You get an upfront price rangeHonest numbers before anyone is dispatched.
- 3
A background-checked tech heads outLicensed & insured, dispatched right away.
- 4
You approve before work beginsNothing starts until you say go.
How Gelco Products Fail - and How We Fix Them
- Gelco GL gas inserts: pilot assembly carbon fouling. The GL-series standing pilot sits in a narrow recess that collects Kirkland’s fine particulate during shoulder-season cycling. Homeowners report the pilot lights, the burner won’t, and a previous tech already replaced the thermopile. We pull the pilot bracket, clean the orifice with a #79 drill bit (not a wire brush, which widens the orifice and voids the gas-valve warranty), and test flame rectification with a microamp meter. If the thermopile’s below 325 mV closed-circuit, we replace it with an OEM White-Rodgers part, not a universal kit that clips the leads too short for the GL’s cramped firebox.
- Gelco GD direct-vent units: failed pressure switches from moisture intrusion. The GD-series concentric vent terminal has a weep hole that clogs with cottonwood fluff common along Kirkland’s Cross Kirkland Corridor in June. Pressure switch failure reads as an ignition lockout, and many techs replace the board first at $400+. We check the manometer reading at the test port first; if it’s below 0.85″ WC, we clear the terminal, verify the combustion-air intake isn’t drawing from a soffit vent, and replace only the switch if it fails a bench test. The camera doesn’t lie, and neither does the invoice.
- Gelco wood-burning fireboxes: refractory panel cracking at the rear wall. The factory refractory in pre-2015 Gelco wood units is a 1.25″ vermiculite board that shrinks through repeated thermal cycling, especially in Kirkland homes that burn Douglas fir with its high resin content. Hairline cracks under 1/8″ we monitor; anything wider gets replaced with HeatShield refractory replacement panels rated to 2,200°F, not the thinner aftermarket boards that delaminate in two seasons. We photograph the crack width with a reference scale and include it in your written record.
- Gelco chimney-top dampers: cable fraying at the 90-degree guide. Gelco’s top-sealing damper uses a stainless cable that runs down the flue to a control handle. The cable guide at the smoke-shelf elbow is unlined on early units, and after 8-10 years the cable frays where it contacts the masonry edge. We find this during our camera scan - the fray shows as a bright wire brush on the video - and replace with a DuraFlex cable assembly with a polymer guide sleeve. Attempting to lubricate a frayed cable just sends rust down the flue and stains the hearth.
- Gelco blower assemblies: motor bearing failure from dust loading. The C-015 blower in many Gelco inserts draws combustion air across the motor; Kirkland’s pollen seasons load the squirrel cage until the motor overheats. The symptom is a blower that rattles, then quits, then works again when cold. We remove the assembly, measure shaft runout with a dial indicator, and replace the motor only if it’s above 0.003″ - otherwise we clean the wheel, balance it, and replace the sleeve bearings with OEM ball-bearing upgrades that last through twice the dust load.
Our Gelco Fireplace Services Process

- 1
Call and schedule. A live person answers, checks Gelco parts availability for your model series, and books a two-hour window. You get a text when your tech is en route.
- 2
Camera-scan inspection. We run a chimney camera per NFPA 211 Level 2 standards, documenting the flue liner, smoke chamber, and firebox. For gas units, we add a combustion analysis - CO in ambient air, gas pressure at the valve, and spillage at the draft hood.
- 3
Written diagnosis and price. Before any repair, you receive a written scope with line-item pricing: parts (OEM or quality aftermarket, your choice), labor, and warranty term. Clause 1 of the Haven Standard requires this in writing before work starts - no exceptions.
- 4
Repair with documented steps. Your tech performs the work, photographing critical steps: the cracked refractory before removal, the new pressure switch manometer reading, the blower balance check. These go into your job record.
- 5
Testing and sign-off. Gas units get a full combustion test rerun; wood units get a draft and smoke-pencil check. You sign the completed scope, and we email your photo record within 24 hours.
- 6
365-Day Done Right Promise. If the same symptom returns, we return. Clause 4 of the Haven Standard requires the photo record; the 365-Day Promise requires we stand behind what we did.
Before
AfterWhat Gelco Fireplace Services Costs in Kirkland
| Service | Typical Range | What Moves the Price |
|---|---|---|
| Gas fireplace tune-up and safety check | $195 - $285 | Accessibility of gas valve, need for combustion analysis |
| Pilot assembly cleaning or replacement | $180 - $340 | OEM vs. aftermarket thermopile, firebox disassembly depth |
| Blower motor replacement | $320 - $480 | OEM Gelco motor vs. aftermarket cross-reference |
| Refractory panel replacement (wood unit) | $680 - $1,200 | Panel count, whether smoke chamber needs parging |
| Top-sealing damper repair/replacement | $450 - $850 | Flue diameter, need for new cable vs. full assembly |
| Pressure switch and vent terminal service | $240 - $420 | Board damage from repeated lockout cycles |
Every estimate is free. We don’t charge to look, and we don’t charge to tell you nothing’s wrong. Bring us a competitor’s written quote for a Free Second Opinion - we’ll review their scope against what our camera found.
Why Kirkland Homeowners Call Level Two Chimney Kirkland for Gelco Work

We’ve inspected and cleaned more than 38,000 chimneys since 2009, and a surprising number of those are in Kirkland neighborhoods like Juanita Beach and Houghton where older Gelco units came with the house. Corrine Halstead learned the trade at Apex Technical School in Manhattan and has spent over a decade on flues in this region. She and her crew know that a Gelco GL pilot issue isn’t always a bad valve, and that Kirkland’s wet winters accelerate refractory deterioration in wood units that owners assumed were “basically gas now.”
Our background-checked, uniformed technicians carry license numbers on every page and every truck. Materials come through our Haven Standard buying network - Gelco, DuraFlex, HeatShield, Olympia Chimney, Famco, Copperfield - so we’re not captive to a single brand’s parts markup. The 365-Day Done Right Promise is stamped on every job. Calls are answered live, 24 hours a day.
FAQs
No - routine service by an independent provider does not void your Gelco warranty, provided OEM-spec parts are used for any covered-component repair and documentation is kept. We use OEM or equivalent-grade parts and photograph every step for your records. If a warranty claim arises, your photo record and written scope support it. Call (425) 642-3485 if you need documentation for a warranty submission.
Common Gelco parts - thermopiles, blowers, refractory panels - ship to our Kirkland warehouse in 2-4 business days through our Haven Standard buying network. Older or discontinued series may take 7-10 days; we’ll tell you before booking if your part is on extended lead time. We don’t start work until the correct part is in hand.
We recommend replacement when the repair exceeds 60% of a comparable new unit installed, or when the firebox is cracked through to the outer shell. For most Gelco units under 20 years, repair is the better value - especially for gas inserts where the venting is already correctly sized. Our camera inspection shows you exactly what we found; we’ll say plainly when work can safely wait.
Gas Gelco units should be inspected annually and cleaned every 2-3 years depending on use; wood-burning units need annual sweep and inspection per NFPA 211. In Kirkland, where many homeowners burn fir with high resin content, we often find Class II creosote at 10 months - not the 12-14 months owners expect. The inspection finds it; the written record proves it was checked.
Gas units accumulate dust on blowers and pilots, leading to incomplete combustion and elevated CO risk; wood units build creosote, which ignites at 451°F and can crack the flue liner. Neither failure gives warning. We find both conditions regularly in Kirkland homes where the fireplace “worked fine last winter.” Call (425) 642-3485 for a free estimate - estimates are free, and so is the peace of mind of knowing what’s actually in your flue.
Written by Corrine Halstead, Owner, Level Two Chimney Kirkland at Level Two Chimney Kirkland, serving Kirkland and nearby areas.





Before
After
Before
After
Before
After