Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Copperfield Chimney Cap Installation: The Kirkland Owner’s Guide
We stock and install Copperfield-compatible chimney caps for most residential flue configurations in Kirkland, with typical installed pricing from $340 to $620 depending on cap size, flue count, and whether the crown needs repair before mounting. Most single-flue replacements we book are completed same visit once the cap is on the truck. Homeowners usually discover the problem during a hard rain: water staining the firebox, a rust streak running down the brick, or the cap sitting crooked after a windstorm off Lake Washington loosened the fasteners.
Which Copperfield Models This Applies To
Copperfield caps fall into three main series you’ll see on Kirkland homes: the standard galvanized single-flue models (8″×8″ through 13″×13″ common), the stainless multi-flue shelters with 24″ to 36″ base widths, and the wind-resistant draft-inducer caps popular in exposed hillside installations near Finn Hill and Bridle Trails. The critical identifier is the stamped model number on the underside of the mesh skirt, not the top lid, since lids get swapped between generations.
We source Copperfield caps through Haven’s buying network alongside DuraFlex, HeatShield, and Gelco lines. For most Kirkland replacements, we match OEM spec unless the original used a discontinued fastener pattern. In those cases we spec a stainless equivalent with a universal base plate, which installs cleaner and outlasts the galvanized original in our wet winters. The wrong move is buying by lid diameter alone; the mesh height and base flange width determine whether the cap seals or creates a new leak path.
Signs Your Copperfield Chimney Cap Is Failing

- Water in the firebox after rain. The cap’s mesh screen has separated from the base flange, or the lid overhang has corroded through at the drip edge. Either gap lets wind-driven rain enter vertically, and in Kirkland’s fall storms off the lake, that means gallons.
- Rust streaks down the chimney face. Galvanized caps lose their zinc layer first at the fastener holes and lid seams. Once steel is exposed, every rain cycle carries iron oxide down the brick, etching the mortar joints if it sits.
- The cap tilts or rattles in wind. The mounting screws have backed out, or the base flange has cracked from thermal cycling. A loose cap is a flying object hazard; we’ve retrieved them from neighbor’s yards after January gusts.
- Birds or squirrels in the flue. Mesh sides have corroded open or been torn by animals testing the gap. Copperfield mesh is 5/8″ standard; if you see larger openings or missing sections, the cap is no longer a barrier.
- Downdraft smoke spillage into the room. Draft-inducer caps can seize if the turbine bearings corrode, or the directional hood can shift out of true. The cap looks intact but no longer creates the pressure differential that keeps smoke rising.
Before
AfterReplacement Cost & What’s Included
| Scope | Price Range |
|---|---|
| Single-flue Copperfield cap, standard install | $340 - $450 |
| Multi-flue shelter cap, 2-3 flues | $480 - $620 |
| Crown repair + cap replacement (needed ~30% of jobs) | $620 - $890 |
| Draft-inducer cap with bearing assembly | $520 - $680 |
What drives the range: cap material (galvanized vs. 304 stainless), flue height above the crown, and whether the existing fasteners pulled out clean or stripped the crown concrete. We inspect with a camera scope before quoting, so you’re not guessing. Every replacement includes new stainless fasteners, a bead of crown sealant at the base flange, and a photo record of the finished mount under Haven Standard Clause 4. Warranty is 365 days on workmanship; the cap itself carries the manufacturer’s defect coverage.
DIY or Call Us?

You can safely check whether the cap is loose from the ground with binoculars, and you can measure your flue opening with a tape measure if you’re comfortable on the roof. What you cannot safely do is remove and replace a chimney cap on a pitched roof above fifteen feet without proper fall protection and ladder positioning. The fasteners are often seized, the crown edge crumbles under torque, and a dropped cap from height is a liability you do not need.
We carry Copperfield-compatible caps on the truck for common Kirkland flue sizes, and we scope the flue interior while we’re up there. The camera doesn’t lie, and neither does the invoice. If the cap is the only problem, we’ll say so. If the crown is soft or the flue liner is cracked, you’ll see it on the screen before we price any additional work. Call (425) 642-3485 for a written estimate with no dispatch fee.
FAQs
Galvanized models typically show corrosion at year 7 to 10 in our climate; stainless versions often reach 15 to 20 years if the crown drainage is good. Salt air exposure from homes near Juanita Beach or Lake Washington can shorten that by a few seasons. Call (425) 642-3485 and we’ll assess what’s on your flue now.
Mesh can sometimes be spot-welded and fasteners replaced if the base flange is solid, but lid corrosion and structural cracks are replacement indicators. We don’t quote repairs that won’t last two full winters; the camera inspection shows which category you’re in. Call (425) 642-3485 for an honest read.
Most single-flue replacements take 45 to 90 minutes including inspection and documentation. Multi-flue shelters or crown-prep work can run two to three hours. We book by the job, not the clock, so the price we write down is the price you pay.
We stock the common single-flue and multi-flue sizes for Kirkland’s typical flue dimensions; specialty draft-inducer or oversized models may need one business day to pull from Haven’s distribution. We’ll confirm availability when you call and schedule accordingly.
Written by Corrine Halstead, Owner, Level Two Chimney Kirkland at Level Two Chimney Kirkland, serving Kirkland and nearby areas.





Before
After
Before
After
Before
After